Pathway DMX Pathfinder CR Manual Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Oprogramowanie Pathway DMX Pathfinder CR Manual. Pathway DMX Pathfinder CR Manual User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
DMXPathfinder CR
DMX DISTRIBUTION SYSTEM{PRIVATE }
OPERATION AND MAINTENANCE INSTRUCTIONS
MANUAL ORGANIZATION ........................................................... 2
1. OPERATION
1.1 SYSTEM OVERVIEW ........................................................ 3
1.2 THEORY OF OPERATION .................................................. 6
1.3 PATCHING TECHNIQUES .................................................. 14
1.4 BI-DIRECTIONAL SYSTEMS .............................................. 18
1.5 BASIC TROUBLESHOOTING .............................................. 19
2. MAINTENANCE AND TESTING
2.1 PREVENTIVE MAINTENANCE ............................................ 25
2.2 TEST PROCEDURES ......................................................... 26
2.3 ADVANCED TROUBLESHOOTING ...................................... 28
3. DMXPathfinder HARDWARE
3.1 THEORY OF OPERATION .................................................. 30
3.2 MODULE DESCRIPTION .................................................... 32
3.3 SCHEMATICS .............................................……………...... 40
4. DMX-QConnect SOFTWARE USERS GUIDE
5. SYSTEM DRAWINGS
Przeglądanie stron 0
1 2 3 4 5 6 ... 38 39

Podsumowanie treści

Strona 1 - DMXPathfinder CR

DMXPathfinder CR DMX DISTRIBUTION SYSTEM{PRIVATE } OPERATION AND MAINTENANCE INSTRUCTIONS MANUAL ORGANIZATION ...

Strona 2 - MANUAL ORGANIZATION

DMX Distribution System Page 10 Operation (daisy-chain) topology to avoid the troublesome effects of signal reflection c

Strona 3 - SECTION 1 -- OPERATION

DMX Distribution System Page 11 Operation described, all of these channels include a separate circuit for communications

Strona 4

DMX Distribution System Page 12 Operation Figure 1-2: Simple 1-in 4-out Opto-Repeater Application

Strona 5 - 1.2 THEORY OF OPERATION

DMX Distribution System Page 13 Operation Figure 1-3: Simple DMX Network with Terminators 1.3 PATCHING TECHNIQUES

Strona 6

DMX Distribution System Page 14 Operation Proper use of the DMX Distribution System involves the electronic routing,

Strona 7

DMX Distribution System Page 15 Operation Remember that end-of-line termination is necessary on all individual DMX c

Strona 8

DMX Distribution System Page 16 Operation unpatched in the DMX-Q patch file, and the Input Module's channel must no

Strona 9

DMX Distribution System Page 17 Operation Figure 1-4: Output Frame Showing Locations of Connectors and Indicator

Strona 10 - Operation

DMX Distribution System Page 18 Operation 1.4 BI-DIRECTIONAL SYSTEMS The DMX Distribution System has been designed

Strona 11

DMX Distribution System Page 19 Operation 1.5 BASIC TROUBLESHOOTING Basic fault-finding at the system user level is

Strona 12

DMX Distribution System Page 2 Manual Organization MANUAL ORGANIZATION This Manual is intended to provide the user or tech

Strona 13 - 1.3 PATCHING TECHNIQUES

DMX Distribution System Page 20 Operation .1 Module Replacement Should a defective Output Module or other module b

Strona 14

DMX Distribution System Page 21 Operation Figure 1-5

Strona 15

DMX Distribution System Page 22 Operation Figure 1-6

Strona 16

DMX Distribution System Page 23 Operation Figure 1-7

Strona 17

DMX Distribution System Page 24 Operation Figure 1-8

Strona 18 - 1.4 BI-DIRECTIONAL SYSTEMS

DMX Distribution System Page 25 Maintenance and Testing SECTION 2 -- MAINTENANCE AND TESTING 2.1 PREVENTIVE MAINTENAN

Strona 19 - 1.5 BASIC TROUBLESHOOTING

DMX Distribution System Page 26 Maintenance and Testing System testing by maintenance personnel will usually be carrie

Strona 20

DMX Distribution System Page 27 Maintenance and Testing instrument will test cable continuity on all five XLR pins. Plea

Strona 21

DMX Distribution System Page 28 Maintenance and Testing 2.3 ADVANCED TROUBLESHOOTING As described earlier, basic tro

Strona 22

DMX Distribution System Page 29 Maintenance and Testing suspect cable runs. This test will quickly indicate any anomalie

Strona 23

DMX Distribution System Page 3 Operation SECTION 1 -- OPERATION 1.1 SYSTEM OVERVIEW The application of recent adv

Strona 24

DMX Distribution System Page 30 DMXPathfinder - Hardware SECTION 3 -- DMXPathfinder HARDWARE 3.1 THEORY OF OPERATION

Strona 25 - 2.2 TEST PROCEDURES

DMX Distribution System Page 31 DMXPathfinder - Hardware possible DMX signals on the I/O bus will be routed first to anot

Strona 26

DMX Distribution System Page 32 DMXPathfinder - Hardware .1 MASTER CONTROL MODULE -- DMS-MCM The main functions

Strona 27

DMX Distribution System Page 33 DMXPathfinder - Hardware repeat a hardware reset from the pushbutton to the Input Modules

Strona 28 - 2.3 ADVANCED TROUBLESHOOTING

DMX Distribution System Page 34 DMXPathfinder - Hardware .2 FRAME CONTROL MODULE -- DMS-FCM The main function of

Strona 29

DMX Distribution System Page 35 DMXPathfinder - Hardware connected to the backplane via J1 to be used for active terminat

Strona 30 - 3.1 THEORY OF OPERATION

DMX Distribution System Page 36 DMXPathfinder - Hardware provided for every connection. Relay status is returned to the

Strona 31 - 3.2 MODULE DESCRIPTION

DMX Distribution System Page 37 DMXPathfinder - Hardware the exception of "RUN" are controlled by the microproc

Strona 32

DMX Distribution System Page 38 DMXPathfinder - Hardware module's four data I/O subsections. Optocouplers U27, U31,

Strona 33

DMX Distribution System Page 39 DMXPathfinder - Hardware .6 SYSTEM COM BUS and I/O BUS In multi-frame systems,

Strona 34

DMX Distribution System Page 4 Operation .3 A means of "patching" or “routing” a number of DMX control sig

Strona 35

DMX Distribution System Page 5 Operation 1.2 THEORY OF OPERATION

Strona 36

DMX Distribution System Page 6 Operation In order to gain a full understanding of the how the DMX Distribution System

Strona 37

DMX Distribution System Page 7 Operation RS485, 100 ohms for RS422A). The main difference is that RS485 is capable of h

Strona 38

DMX Distribution System Page 8 Operation on the communications channel. Each input signal always occupies the same fram

Strona 39

DMX Distribution System Page 9 Operation systems since the early 1980s. Included are Avab A-240, Colortran CMX (also ca

Komentarze do niniejszej Instrukcji